Electrics in the bathroom: understanding the safety zones

Black shower room with a double basin, renovated by Pollux

Zones 0, 1 and 2, 30 mA residual current protection, earth bonding: the rules of the French NF C 15-100 standard to know before renovating a bathroom.

A bathroom combines water and electricity. The French NF C 15-100 standard divides the room into safety zones that determine where sockets, lights and appliances may go. Knowing them helps design a bathroom that is both beautiful and compliant.

Zone 0: where the water is received

This is the inside of the bath or shower tray. Only safety extra-low voltage equipment (12 V) protected against immersion (IPX7) is allowed there, for example 12 V lighting. No socket, no switch, no mains appliance.

Zone 1: above the shower or bath

It extends above zone 0 up to 2.25 m from the floor. Lighting and switches at 12 V are allowed there, as well as a class I water heater under certain conditions.

Zone 2 and outside the zones

Zone 2 borders zone 1: class II lighting, class II heating and a shaver socket with an isolating transformer are possible there. Beyond it, outside the zones, earthed sockets, switches and a washing machine are allowed.

30 mA residual current device and earthing

The bathroom circuits are protected by a 30 mA residual current device. Pipes, metal parts and the room's lights are connected to earth.

What it changes for the room's design

The position of the lit mirror, the hairdryer socket, the heated towel rail, the washing machine: everything is decided with the zones in mind, before tiling. That is why Pollux handles electrics, plumbing and finishes within the same project.