Skip to content
Menu FR

Kitchen

Kitchen electrics: sockets and circuits to plan

Granite worktop and hob in a kitchen renovated by Pollux

How many sockets, where to place them, which circuits for the hob, the oven or the dishwasher: the benchmarks of the French NF C 15-100 standard for a kitchen.

A kitchen concentrates the most powerful appliances in the home. Planning the sockets and circuits before designing the units avoids extension leads, drilled skirting boards and redone tiling.

At least six sockets, four of them above the worktop

The French NF C 15-100 standard requires at least six sockets in the kitchen, supplied by a dedicated circuit, four of them above the worktop. A kitchen of less than 4 m² can make do with three sockets.

Forbidden positions

No socket above the sink or above the hob, except the cooker hood socket placed at least 1.80 m from the floor. Sockets stay no higher than 1.30 m from the floor.

Dedicated circuits for large appliances

The oven, dishwasher, washing machine and cooker hood each have their own 16 A circuit. The hob or cooker needs a more powerful circuit: 32 A single-phase or 20 A three-phase, with 6 mm² conductors. Each circuit has its own circuit breaker, and the whole installation is protected by a residual current device.

Design the units together with the services

The position of the hob, sink and oven determines that of the circuits and waste pipes. That is why Pollux handles plumbing, electrics and bespoke units within the same project.

Kitchen renovation with Pollux.

Sources


Further reading

WhatsAppMessage Ionuț Mircea

Search the site

pollux.d3sign